HYD - 12 HYDRAULICS LABORATORY |
| |
| 1. |
I.R.TYPE |
With sump tank, measuring tank and
suitable capacity recirculating pump. |
| 2. |
CONVENTIONAL TYPE |
Without sump tank and pump.
Using Lab. water supply. |
| 3. |
H.L.T.TYPE |
Suitable for use with our common
Hydraulic laboratory tray. |
|
| |
REYNOULDS APPARATUS.
To demonstrate the principal of laminar and turbulent flow and
determination of reynoulds number for various flow rates.
A water supply tank to which a glass tube is connected and enters
at the center of glass tube cross section. For laminar flow condition,
stick is clearly viable but in turbulent flow,the die line diffuse,controlled
by valves and gives clear visualization. |
12011 |
| |
VERIFICATION OF BERNOULLIES THEOREM APPARATUS.
To calculate the energy & head of water at different saction, A unit
consists of a transparent flow channel through which water is made
to flow. The velocity of water changes as cross sectional area of
channel changes. Changes of head are measured with manometric
tubes connected at various tapping to the channel.
|
12021 |
| |
FLOW OVER NOTCHES APPARATUS
A flow channel in which notch fitted. Water is supplied at one end of
channel, which flows over the notch. A setting chamber with dampers
is provided at beginning of flow channel to reduce the pulsations and
to settle the flow.arrangement is provided to measure the sill level of
water & flow level to determine the head. |
12031 |
| |
FLOW OVER WEIR APPARATUS A flow channel in which weir fitted. Water is supplied at one end of
channel, which flows over the weir. A setting chamber with dampers
is provided at beginning of flow channel to reduce the pulsations and
to settle the flow.arrangement is provided to measure the sill level of
water & flow level to determine the head. |
12041 |
| |
FLOW THROUGH ORIFICE & MOUTHPIECE
To determine Cd, Cc, & Cv, of orifice as well as Cd of mouthpiece.
A supply tank to which orifice or mouthpiece fitted. Tank with flow
settling arrangement. A tracer pointer to demonstrate & determine
x-y Co-ordinates of jet. Arrangement is provided to vary and measure
the head over orifice or mouthpiece.
|
12051 |
| |
FLOW MEASUREMENT BY VENTURIMETER AND ORIFICEMETER
A unit consists a supply piping connected to a transparent venturi and orifice. tappings to measure pressure difference across venturi and orifice which are connected to differential manometer.
The actual flow rate can be measured with the help of measuring tank
and both the meters can be calibrated.
|
12061 |
| |
LOSSES IN PIPE FITTINGS
To study of loss of head in various pipe fittings, the apparatus consists
of a piping providing with a various fittings. A differential manometer
supplied to measure the loss of head in these fitting. A flow control
valve is provided which enables experimentation at various flow rates.
Sufficient settling length for accurate readings.
|
12071 |
| |
LOSSES IN PIPE FRICTION
To study the effect of velocity over the head loss. A unit consists of
G.I. pipes of same length but two different diameters and one pipe
are copper and aluminium each. Piezometric tubes to measure the
head at tappings to compare the head losses for various material and pipe diameters. |
12081 |
| |
FLOW THROUGH SUBMERGED ORIFICES |
12091/92/93 |
| |
FLOW THROUGH HELICAL COIL |
12101/02/03 |